BaroVUE10 Digital Barometer
Perfect for Environmental and Meteorological Applications
User friendly, cost effective, and best-in-class accuracy and stability
weather applications supported water applications supported energy applications supported gas flux and turbulence applications supported infrastructure applications supported soil applications supported

Overview

The BaroVue™10 is a highly accurate barometer that can measure pressures over a range of 500 to 1100 hPa and can be used in a range of applications that includes meteorology and hydrology. This sensor includes our zero downtime recalibration. Other sensors on the market need to be taken offline and sent back to the manufacturer to be recalibrated, often for weeks at a time, causing a loss in valuable data and time, as well as an additional expense. 

The sensor card for the BaroVue 10 is pre-calibrated. Replacement sensor cards are also pre-calibrated, requiring only one trip to the field station and no downtime. The design of the BaroVue 10 allows you to remove and replace your sensor card quickly and easily without either having to disassemble the equipment in the enclosure or having to send the equipment back to the manufacturer.

Read More

Benefits and Features

  • Highly reliable measurements (multiple cells)
  • Direct-to-digital measurements
  • Very low noise
  • Integrated identification and diagnostics
  • Zero downtime/recalibration
  • Easy firmware updates
  • Cost effective
  • SDI-12 device

Images

BaroVue 10 with Ships With items

Technical Description

The BaroVue 10 is a low-power, digital barometer (-40 to +60°C) that provides best-in-class accuracy and stability (±0.1 hPa/yr) over the entire pressure and temperature range. It can run continuously and does not require power cycling unlike other products in this category. The digital output is both SDI-12 and RS-232, which reduces noise and measurement uncertainty compared with analog sensors, and makes the BaroVue 10 compatible with all Campbell Scientific SDI-12 devices. Moreover, this barometric pressure sensor can be installed and integrated into many new and existing weather stations. The transducers used in the BaroVue 10 are direct-to-digital sensors, and no reconversion takes place inside the barometer.

Specifications

-NOTE- These specifications assume the recommended desiccation is used.
Pressure Range 500 to 1100 hPa
Temperature Range -40° to +60°C
Supply Voltage 9 to 28 Vdc
Elevation ~609.6 m (2,000 ft) below sea level (as in a mine) to 4,572 m (15,000 ft) above sea level
Current Consumption
  • < 5 mA (active)
  • 200 µΑ (sleep mode)
Digital Output SDI-12, RS-232 serial
Pressure Fitting Barbed fitting for 0.318 cm (0.125 in.)
Dimensions 2.2 x 9.0 x 10.2 cm (0.87 x 3.54 x 4.02 in.)
Weight 226.8 g (0.5 lb)

Accuracy

Calibration Uncertainty ±0.15 hPa
Uncertainty ±0.3 hPa (at 20°C)
Total Uncertainty ±0.5 hPa (at -40° to +60°C)
Long-Term Stability ±0.1 hPa/yr
Power Supply Rejection Negligible
Measurement Noise 0.05 hPa (RMS)
Resolution 0.1 hPa

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
CR1000 (retired)
CR1000X
CR300
CR3000
CR310
CR350
CR6
CR800 (retired)
CR850 (retired)

Mounting Equipment

Product Compatible Note
ENC100
ENC10/12
ENC12/14
ENC14/16
ENC16/18
ENC8/10

Miscellaneous

Product Compatible Note
DAQ Case 15

Additional Compatibility Information

Downloads

BaroVue10 OS v.1.4 (466 KB) 17-04-2023

Current OS for the BaroVue10.

View Revision History

BaroVue10 Program Example (1 KB) 28-03-2023

Description: Includes an SDI-12 example and a RS-232-serial program example. The programs are written for a CR1000X, but programs for other data loggers will be similar. 

The SDI-12 example uses the C1! command to retrieve data. The program also adjusts the barometric pressure measurement to sea level. The adjustment is entered as a constant, Elevation_m, at the beginning of the program. Initially, the Elevation_m value is 1382; change this value to your site elevation, in meters.

The serial program demonstrates using RS-232 mode to initiate and return measurements using the SerialOut(), SerialIn(), and SplitStr() CRBasic instructions. 

FAQs for

Number of FAQs related to BaroVUE10: 2

  1. The calibration sheet supplied with your BaroVue 10 applies to the sensor card (BVC10). The serial number on the outside of the unit refers to the serial number of the BaroVue 10 main board. To confirm you have the correct calibration sheet, please open the device and check the serial number on the BVC10 sensor card itself.

  2. A CS106 Barometric Pressure Sensor can be added to the station. However, the sensor needs to be wired into the wiring terminal inside the enclosure, and the data logger program needs to be edited to include the instructions to poll the sensor and store the values.

    Note: Some versions of the ET107 station that are interfaced with irrigation companies may have proprietary programs or complicated programs that are not easily changed.


This Product Replaced

Privacy Policy Update

We've updated our privacy policy.  Learn More

Cookie Consent

Update your cookie preferences.  Update Cookie Preferences